SERVICE MANUAL 300TELECTRONICAIR PURIFIERRISK OF ELECTRIC SHOCK!This servicing manual is for use byqualified personnel only. To reduce therisk of elec
E-10ENGLISHPART III IMPORTANT PARTS - PRE FILTERThe pre filter is an important part of the unit. Large particles (lint, hair) are caught by the pre fi
E-11ENGLISHPART III IMPORTANT PARTS - ELECTRONIC CELLThe electronic cell ( electrostatic precipitator) is one of most important parts of the unit. The
E-12ENGLISHPART III IMPORTANT PARTS - ELECTRONIC CELL101801 (x10)101802 (x4)211515 (x35)211516 (x36)211518 (x5)211510211514211513211517 (x12)101507211
PART III IMPORTANT PARTS - ELECTRONIC CELL1. DO NOT clean the cell with alcohol, gasoline, paint thinner or other flammable substances. It may cau
ENGLISHE-14PART III IMPORTANT PARTS - ACTIVATED CARBON FILTERThe activated carbon filter is also one of the important parts of the unit. The activated
ENGLISHE-15PART III IMPORTANT PARTS - UV LAMP AND PHOTO CATALYSTAfter removing the activated carbon filter, you will see a UV lamp behind the UV light
ENGLISHE-16PART III IMPORTANT PARTS - NEGATIVE ION GENERATORThe negative ion generator is secured to the upper portion of the left fan housing by a sc
PART III IMPORTANT PARTS - INTERLOCK SWITCHE-17INTERLOCK SWITCH11221. Unscrew 2 screws on the interlock switch adjustor plate.2. Remove the interlock
PART III IMPORTANT PARTS - MAIN CIRCUIT BOARDE-18Helpful hintsAs long as the circuit board is working, you need not to replace the main circuit board
PART III IMPORTANT PARTS - MAIN CIRCUIT BOARDE-19It is important to remember that the main circuit board will be rarely broken down. For example, when
E-2PART I GENERAL DESCRIPTION ON AIR CLEANINGIf you could see the air you breathe under a microscope, you might be in for a surprise. The air quality
PART III IMPORTANT PARTS - MAIN CIRCUIT BOARDE-20Disassemble main circuit boardInstall main circuit boardWhen install the circuit board, do the revers
E-21Helpful hintsWhen the red check lamp flashes, you need to check the cell and power supply itself. When the green working lamp is lighten up, it sh
E-22Helpful hintsWhen the CHECK indicator light on the control panel flashes you need to open the bottom plate and check the 2 lights on the power sup
PART III IMPORTANT PARTS - POWER SUPPLY AND TRANSFORMERE-23ENGLISHAdjust the power supply high voltage outputElectronic cell generates a small amount
PART III IMPORTANT PARTS - POWER SUPPLY AND TRANSFORMERE-24ENGLISHHelpful hints1. Do not tight up the screws before all the screws are set.2. Before i
PART III IMPORTANT PARTS - POWER SUPPLY AND TRANSFORMERE-25Adjust the power supply high voltage outputElectronic cell generates a small amount of ozon
PART III IMPORTANT PARTS - POWER SUPPLY AND TRANSFORMERE-26Notice:As long as the lamps are lighting up, it means the power supply transformer is OK. Y
PART III IMPORTANT PARTS - FAN MOTOR SYSTEME-27FAN MOTOR SYSTEM1. Taking out the front panel and remove the upper plate.2. Remove the fan motor front
PART III IMPORTANT PARTS - FAN MOTOR SYSTEME-2811. Unplug the fan motor cable connection.12. Lift out the fan motor complete.You need to remove 6 scre
PART III IMPORTANT PARTS - FAN MOTOR SYSTEME-29H speed (Red)M speed (Blue)L speed (Black)Com (Yellow)Motor typePower requirementRated PowerCapacitorCa
E-3PART I GENERAL DESCRIPTION ON AIR CLEANINGA wide variety of molds also can produce mycotoxins at various times during their lifecycles. Building oc
PART III IMPORTANT PARTS - DISPLAY CIRCUIT BOARDE-30ENGLISHDISPLAY CIRCUIT BOARD1. After take off the front panel remove 4 screws on the upper plate.3
PART III IMPORTANT PARTS - DISPLAY CIRCUIT BOARDE-316. Unplug the odor sensor.7. Unplug the remote receiver wire from the display circuit board.9. Uns
PART IV TROUBLESHOOTING - CHECK LIGHT FLASHINGE-32When the unit is turned on, the CHECK indicator light flashes and you may hear warning beep sound.Wh
PART IV TROUBLESHOOTING - CHECK LIGHT FLASHINGE-33ENGLISHCheck power supplyIf you did not find any problem in the cell, go to investigate the power su
PART IV TROUBLESHOOTING - CHECK LIGHT FLASHINGE-34ENGLISHCheck power supply transformerThe CHECK indicator light on the control panel is flashing but
PART IV TROUBLESHOOTING - NO POWERE-35NO POWERWhen the unit is plugged in, there are no display indicator lights on the control panel and no any melod
PART IV TROUBLESHOOTING - NO POWERE-36Check power cord plug and outlet1. Sometimes, the unit does not operate because of the electrical outlet failure
PART IV TROUBLESHOOTING - NO POWERE-37ENGLISHCheck fuseStep 4Replace interlock switchIf the unit still has no power after adjusting the interlock swit
PART IV TROUBLESHOOTING - NO POWERE-38ENGLISHWhy does the fuse keep damaging?After replacing the blown fuse with a new one, try to operate the unit bu
PART IV TROUBLESHOOTING - NO POWERE-39ENGLISHCheck main circuit boardStep 6Check main circuit board transformerStep 5Check main circuit board transfor
E-4ENGLISHPART I GENERAL DESCRIPTION ON AIR CLEANINGWhen you are trying to repair the air purifiers, make sure you understand the technologies used by
PART IV TROUBLESHOOTING - NO FANE-40Fasten the fan motor wire connections or replace the display circuit board.When the unit is turned on, the fan doe
PART IV TROUBLESHOOTING - NO FANE-21No fan with incorrect display lightsWhen the unit is powered on, the display lights show incorrect and some button
PART IV TROUBLESHOOTING - NO FANE-42ENGLISHCheck main circuit board1. Set the ohmmeter at the range of 200V ac.2. With the ohmmeter, check three speed
PART IV TROUBLESHOOTING - NO FANE-43ENGLISHReplace the fan motorIf the motor still does not run correctly after replacing the motor capacitor, you wil
PART IV TROUBLESHOOTING - NO FANE-44ENGLISHCheck the fan motor If the fan motor cable connection is correctly all the connections are correctly connec
PART IV TROUBLESHOOTING - UNIT RESETE-45When the CARBON FILTER (FILTER LIFE) or UV LAMP indicator light flashes you need to replace them. After replac
PART IV TROUBLESHOOTING - UNIT RESETE-46ENGLISHUnit reset button (Just for B model number units)When you cannot reset the unit with remote control, pl
PART IV TROUBLESHOOTING - UNIT RESETE-47ENGLISHStep 3Main circuit board reset buttonPress the button once to reset the FILTER LIFE and hold 5 seconds
PART IV TROUBLESHOOTING - THE BUTTONS DO NOT WORKE-48Repair tips:1. Sparking from the cell 2. Power contact board sparking 1. Check the electronic cel
PART IV TROUBLESHOOTING - NO UV LIGHTE-49Check UV lamp Visually check the UV bulb. If it is broken or damaged replace it. Make sure the UV lamp is in
E-5ENGLISHPART I GENERAL DESCRIPTION ON AIR CLEANINGOzone Molecules converted from oxygen (left) as a result of an electrical charge, such as that pro
PART IV TROUBLESHOOTING - NO UV LIGHTE-501. Stop the operation and unplug the unit power cord from the electrical outlet.2. Take off the front panel.3
PART IV TROUBLESHOOTING - NO UV LIGHTE-51When you find there is no voltage on the UV lamp power cord, you will go ahead to open the bottom plate and c
PART IV TROUBLESHOOTING -ELECTRICAL SHOCKE-52Adjust Pre filter ground clip so that it can contact the Pre filter and cell clips correctly.2. Check ce
PART V APPENDIX - CHANGES OF THE UNITE-53ENGLISHSerial numberR3000001A ~R3000350AFeatures and changes2 RESET buttons1. Press the RESET 1button 5 times
RespirAide Tech Inc.13-100 Hanlan Road Woodbridge, OntarioCanada L4L 4V8Tel: 1-866-874-2532Fax: 1-905-850-5553www.respiraide.com
E-6ENGLISHPART I GENERAL DESCRIPTION ON AIR CLEANINGActivated Carbon FilterThe activated carbon filter can remove gas and odor. This is the physical p
E-7ENGLISHPART I GENERAL DESCRIPTION ON AIR CLEANINGHow photo catalyst worksUV lamp and photo catalyst of 300TPhoto catalyst A photo catalyst is a che
E-8ENGLISH101301101306.Remote Control (Complete)(1 unit).Battery(CR2025X1).Operation Manual21192221120121130121110221180421130421110510131521190521150
E-9ENGLISHPART II PRODUCT INFORMATIONThe sixe stages of air cleaning1. The Pre-filter traps large dust particles.2. The two-stage electrostatic precip